Einleitung

This guide will show you how to disconnect the control link and remove the handle assembly of a Clarke EZ-8 Floor Sander.

  1. AAq6ugauoZErPlVX
    • Before you begin your repair, disconnect all power cables to reduce the risk of short circuits and electric shock.

  2. ygAG4XAnyoAREoY6
    ygAG4XAnyoAREoY6
    eGqq4nGf44Kc2PVu
    • Pull on the dust bag to remove it from the dust tube.

    • If the dust bag doesn't slide off easily, gently twist it back and forth while pulling to free it from the tube.

  3. WEy2NfgJHORfkMu4
    • Pull up on the dust tube to remove it from the sander.

  4. llZjVtwJIOBGvThg
    llZjVtwJIOBGvThg
    Y3h3Wu3v6p2DHtPT
    1oNWt5mSAX3vsSKK
    • Slide the collar on the control link arm up until the two halves of the arm detach from one another.

  5. RKqljxksRdmKZxoM
    RKqljxksRdmKZxoM
    td3gJH4GiehPtVdX
    XCM3whQHnUat3mSv
    • Pull up on the latch at the bottom of the handle assembly, then remove the retaining plate from its slot in the handle.

  6. aBhBFABD3LCCIqyC
    aBhBFABD3LCCIqyC
    lDXtjgG1BEimCRXG
    • Pull up on the handle assembly and remove it from the sander.

Abschluss

To reassemble your device, follow these instructions in reverse order.

Taylor Dixon

Mitglied seit: 26/06/18

63211 Reputation

0 Kommentare