Einleitung

This guide shows how to remove and replace the recoil starter for the Honda 6500 Watt Generator EG6500CL AT.

  1. DmxWmIMhwA22AFBe
    DmxWmIMhwA22AFBe
    XBJ2c5RKBUW5ea1u
    • Before you work on the device, make sure to switch the engine off.

    • Switch the circuit breaker off.

  2. FdF22f2xXhCGrGpE
    FdF22f2xXhCGrGpE
    AG6kDCtri5JHyGkh
    • Grab the plastic housing at the end of the spark plug wire.

    • Pull firmly to disconnect the wire from the spark plug.

  3. S1gJ5ahkvBXNmtZD
    S1gJ5ahkvBXNmtZD
    g6SVhTiJQDAQj3Dt
    • Twist the fuel valve clockwise into the cutoff position.

  4. PNG3nsLCM2T3y3Jk
    • Use a 10 mm socket to remove the three bolts securing the recoil starter.

  5. HQsZwNJUsCjKgRDL
    HQsZwNJUsCjKgRDL
    nZaxlESuIRqdI1H4
    • Remove the recoil starter.

Abschluss

To reassemble your device, follow these instructions in reverse order.