Einleitung

Follow this guide to calibrate the in-screen optical fingerprint sensor in your Motorola phone. You should perform the calibration whenever you replace the screen to ensure that the fingerprint sensor is accurate and secure.

You'll need the fingerprint sensor calibration toolkit in order to complete this procedure.

  1. A4Ew4IDeH5iV51Gd
    A4Ew4IDeH5iV51Gd
    lLgTMYRTeqNxERpu
    • Open the phone app.

    • Open the dial screen.

    • Enter *#*#2486#*#* on the dial pad.

    • If the CQATest menu doesn't come up immediately, press "Call".

  2. lE2dGoKkqoAMbS1J
    • If any pop-ups appear, allow them.

    • Select "CQA Menu Mode" from the options.

  3. m6iPt4jnvIuVFDLF
    • Select "Sensor" from the options.

  4. EDJMukReegi2LFLb
    • Select "Fingerprint Egis Fod SMTP" from the options.

  5. 6AIRAfgBM4fQ41Vi
    6AIRAfgBM4fQ41Vi
    Td1MXQTRHRyHybuJ
    yPOwQjx1ENwctQco
    • Press "START" on the top left corner of the screen.

    • You should see a menu that says "Normal Scan: ok, click NEXT" with a list of tests under it.

    • If any of the tests failed, restart from the beginning of this guide.

    • Press "NEXT" on the top right corner.

    • Wait until the message at the top of the screen changes to "Put FLESH FLAT, click NEXT".

  6. KXpdrdyDY2Vc2Hjx
    KXpdrdyDY2Vc2Hjx
    GDOGIWtDFAFTUTOO
    mxQMxVvKgOZ3AYtJ
    • For the next two steps, make sure you're using the pink box that has a small square indented in it and not the pink box that has grooves.

    • With the indented side facing down, place the pink box over the red box on the bottom of the screen.

    • Make sure the pink box covers the red box as much as possible. Deviations could result in a "Fail" result or an inaccurate calibration.

  7. akFpjpqWMAVixAHL
    akFpjpqWMAVixAHL
    1gR2fLendrrMsRHY
    • Press down on the pink box with your thumb.

    • While pressing down on the box, use your other hand to select "NEXT" on the top right of the phone.

    • Continue pressing down on the box until the message at the top of the screen changes to "Put BLACK FLAT, click NEXT".

  8. DOY54vhbSTMTGFYx
    DOY54vhbSTMTGFYx
    aLAD3PmUu2C3oyp1
    2cHeqqCaJ5YjTKHV
    • With the indented side facing down, place the black box over the red box on the bottom of the screen.

    • Make sure the black box covers the red box as much as possible. Deviations could result in a "Fail" result or an inaccurate calibration.

  9. NPWBeh3ucTBNIhCh
    NPWBeh3ucTBNIhCh
    RCSjXVZUnW4WwLwD
    • Press down on the black box with your thumb.

    • While pressing down on the box, use your other hand to select "NEXT" on the top right of the phone.

    • Continue pressing down on the box until the message at the top of the screen changes to "Put FLESH CHART, click NEXT".

  10. Ma4AoVOflWQ4Ko1i
    Ma4AoVOflWQ4Ko1i
    VPUEoqmdljydYurf
    gbdTQu5vH335qMLm
    • For the next two steps, make sure you're using the pink box that has grooves and not the pink box that has a small square indented in it.

    • With the grooved side down and the grooves vertical, place the pink box over the red box on the bottom of the screen.

    • Make sure the pink box covers the red box as much as possible. Deviations could result in a "Fail" result or an inaccurate calibration.

  11. hGNLHgT2IXEfKawt
    hGNLHgT2IXEfKawt
    wfRuNEUrXIhQBxSf
    • Press down on the pink box with your thumb.

    • While pressing down on the box, use your other hand to select "NEXT" on the top right of the phone.

    • Continue pressing down on the box until you get a message about the calibration results.

  12. uCgANYZhWhUmKXJw
    uCgANYZhWhUmKXJw
    SrSasXe2nqlTK5PL
    • You will see "Calibration test: ok" if the calibration was successful.

    • If you see "Calibration test: fail" at the top of the screen, restart from the beginning of this guide.

Abschluss

Your optical fingerprint sensor is calibrated and ready for use.