Einleitung

If your sink is slow to drain or is not draining, the cause may be a clog in the P-trap. Use this guide to disassemble and clear any clogged hair and soap scum from the P-Trap.

The P-Trap is P shaped piping that directly follows the drain stopper and is usually located in the cabinets below a sink. The P-Trap is mainly intended to hold water in the bend with the intent of blocking foul smelling air from deeper within the plumbing of a house from coming out through the sink. It also serves the secondary purpose of catching small items dropped into the sink and allowing them to be retrieved.

Before beginning, ensure water to the sink being worked on is shut off and that your workspace is prepped for any potential spills.

  1. VnCMoxULJueRD3X3
    • Clear out the space if the trap is located in a hard-to-reach place.

    • Turn off the water valve for the sink.

  2. GEIXTIOyD1DMJDtD
    • Place towels around the area.

    • Place a bucket or bowl under the P-trap.

  3. 6PHMxYnIaOFJw3Gq
    6PHMxYnIaOFJw3Gq
    uHH2ZrLRVMBMptpd
    uhCNuxvnKgUiMYUB
    • Loosen the coupling nuts from the pipe above and below the drain using a wrench.

  4. pJQXtk1AjNMNEKyU
    pJQXtk1AjNMNEKyU
    6FXAHkidxAAXofGy
    fYL4FWJBcbAufheG
    • Loosen the nuts on the upper and lower pipe and disconnect the the P-trap.

    • Remove the U shape from the piping, and dump any water into bowl.

    • Pull the PVC pipe that is connected to the wall out horizontally.

    • Pull the PVC pipe closest to the drain in a downward motion.

  5. vLTpFY3UdFk5EK4G
    vLTpFY3UdFk5EK4G
    iJRbn42wfot6FDLv
    NZxUod1BpwVPYXqE
    • Empty any water into a bucket.

    • Clear out the interior of the PVC pipe using a bottle brush or wire, spinning and moving the brush through the pipe.

    • Remove any soap scum.

    • This may appear black and sludge-like.

  6. KIMlPRUYAW4AvaR4
    KIMlPRUYAW4AvaR4
    5bCQFAEs5WW4q3SD
    J3i12nYxvRRlKZdB
    • Using a different water source, run the hot water through the P-trap parts.

    • Check that the P-Trap parts are clear.

  7. ohv1YkWxOFimYuRA
    ohv1YkWxOFimYuRA
    ZRhZDkhnIZj5QYgi
    HdmVjutAmN4rQNFT
    • Reassemble the trap, but leave the horizontal pipe disconnected.

    • Insert the short pipe into the the U shape and loosely tighten the nut.

  8. HRccXtHnRYafyIiO
    HRccXtHnRYafyIiO
    jZjfPFaGEqoa1PGp
    1VEabuVFXsYqFPkc
    • Insert the horizontal pipe back into the water output in the wall. Begin to tighten the nut closest to the wall.

  9. lwKv2PNAHTaiUNB6
    lwKv2PNAHTaiUNB6
    QmvhspVa3qXYPl5b
    ymX5WmMLN5h4Bvsh
    • Insert the top of the P-trap back onto drain pipe.

    • Align the pipes so the pipes are touching.

    • Once aligned, secure all the nuts tightly.

  10. j2xUvPYgGg5FSYij
    j2xUvPYgGg5FSYij
    TnFEMRCOLIuFMDLW
    • Turn the water valve back on to check the P-Trap for leaks.

    • Run hot water for 30 seconds or more, and use your hand to feel for any leaking.

    • If you do, identify which section is leaking and tighten the nut.

    • If it continues to leak, you may need to use threading tape, which is shown in the next step.

  11. ynW2pIrWILRg5NQC
    ynW2pIrWILRg5NQC
    iYckIcD5eFf5gbrC
    cGAKv6Fv5FhKfCos
    • Take the P -trap off after locating the leak.

    • Use the threading tape on the PVC pipe to help the nuts tighten. Simply wrap the threading tape around the threading on the pipe where the leak was found.

    • Put the PVC P-trap back on and tighten the nuts.

    • Turn the water back on as you check for leaks.

    • wrap the tape in a clockwise direction around the pipe threads.

  12. gQnNNvFM1xTsrReW
    • Put the P trap back into place.

    • Give the P-trap one more look to ensure all the nuts are tightened.

    • Double check alignment and you are finished.

Abschluss

To reassemble your device, follow these instructions in reverse order.

Ashley m. Wuthrich -Hoffman

Mitglied seit: 18/11/21

229 Reputation

0 Kommentare