This guide will allow the reader to how to disassemble the Nikon Coolpix S5300 and get to its button panel.

  • Make sure to be gentle when removing ribbon cables.
  • Be sure to keep track of all your screws.
  1. Kb5R6n1YM6rPl2u4
    • Turn the camera upside down and locate the battery compartment.

    • Slide the compartment open following the direction of the arrow.

  2. PlXdQYBKAvOnvphD
    • Press the orange release button to release and remove the battery.

    • Replace or insert battery in it's respective terminals

  3. 1AOfexVGTRjQEEeD
    1AOfexVGTRjQEEeD
    N5HmjERx2WOhYsFb
    aRcMCEHBtrAk6MZb
    • Remove the four 0.1mm screws from the bottom of the camera using the phillips head screwdriver

    • Using the same screwdriver, remove the 2 screws on the side of the camera.

    • Remove the 2 screws from the other side of the camera.

    • One of the screws is under the I/O port cover.

  4. NjiL1cJ2cbbpDnTk
    NjiL1cJ2cbbpDnTk
    kwR6KqN55QrPiODM
    EOMGTZvBRRiEEvSs
    • Use the plastic opening tool to carefully separate the cover from the camera.

    • Work the plastic opening tool around all the edges of the front plate.

    • Pull the purple plastic cover off gently from the screen.

  5. JCNKxURxlVNFLCZV
    JCNKxURxlVNFLCZV
    4RBbGY6GIRBS2odi
    Oh2dhqDThimRbIXj
    • Turn the camera over so the LCD screen is facing you.

    • Carefully remove the front shell by gently prying around the corners with the plastic opening tool until it releases.

  6. sZ3mNTglWyjPQY11
    sZ3mNTglWyjPQY11
    V5ndpRGL2N2fT62k
    • Be careful to keep track of little pieces of the outside casing.

  7. 6X4tawaIQoQBVmqN
    6X4tawaIQoQBVmqN
    GIPISNhSJkiaar6P
    • Carefully remove the top button casing by pulling it away from main camera.

  8. Xn2WgqEY6FN1gBrL
    • Remove the 2 screws on the silver plate

    • Gently lift the screen and silver plate away from the internal components.

    • Do not separate the plate and screen from the camera

  9. okPXyKXjpaIPRBhf
    okPXyKXjpaIPRBhf
    oNWPgCTnDGtiZ3aF
    • Carefully move the button panel away from the silver plate.

    • To disconnect the ribbon cable, use the tip of a plastic opening tool or your fingernail to flip up the small retaining flap.

    • Safely pull the ribbon cable out and then remove the button panel.

    • Be sure you are prying up on the hinged retaining flap, not the connector itself.

Abschluss

To reassemble your device, follow these instructions in reverse order.