This guide will show you how to test and replace a faulty switch on a Revlon 473 Hair Dryer.
A faulty switch not only limits operation, but it is also a fire hazard. If the power switch on your Revlon 473 Hair Dryer isn't functioning, a switch replacement can improve the operation and safety of the unit.
Disconnect the Revlon 473 from any power source before you begin this repair.
Werkzeuge
-
-
Separate the shell from the main component.
-
Check to ensure each piece is free from debris.
-
-
-
Bring the probes toward each switch to test for continuity.
-
If the numbers on the multimeter continue to change, the circuit is closed and the switches are functioning.
-
If the meter stays at a set number, the circuit is open, and the switch needs to be replaced.
-
To reassemble your device, follow these instructions in reverse order.