Einleitung
If your camera's LCD is not working properly and the display has black spots or is all white you may need to replace it. Before taking apart the camera, make sure the power is off and the battery is removed.
Werkzeuge
-
-
Locate the bottom panel of the camera.
-
Unscrew the four 4.5mm Philips #000 (perpendicular cross) screws with the Philips #000 screwdriver.
-
-
-
Unscrew the three 4.5mm #000 Philips screws on the sides of the camera using the Philips #000 screwdriver.
-
-
-
Remove the ribbon by lifting the grey tab on the ZIF connector with the metal spudger.
-
Push the ribbon out of its socket with the plastic opening tool.
-
-
-
Remove all five 3mm Philips #000 screws from the inside of the back panel using the Philips #000 Screwdriver.
-
-
-
Lift up the grey tab on the ZIF connector with the spudger to remove the ribbon.
-
Using both thumbs push the ribbon out of the ZIF connection.
-
-
-
Use the metal spudger to pick the bottom of the plastic piece while simultaneously using your index finger to push down on the larger metal slab. This will cause the metal plate with the large ribbon to slide down and out of the plastic back panel.
-
-
-
Use a metal tool to pick on the sides of the metal plate to remove the plate from the plastic tabs.
-
To reassemble your device, follow these instructions in reverse order.