Einleitung
If your power cord is broken and your blender will not turn on, follow these steps to replace it.
Werkzeuge
-
-
With the bottom of the blender facing up, use a Phillips #2 screwdriver to remove the 4, 1/2 inch long screws in the corners of the device.
-
-
-
Using the same Phillips #2 screwdriver, unscrew the 1/2 inch long screw under each of the feet.
-
-
-
On the underside of the base, unscrew the three 3/8" long screws on the plastic piece holding the power cord in place using a Phillips #1 screwdriver.
-
Pull the plastic cover off.
-
-
-
Pull the cut power cord through the base.
-
Then thread the replacement cord back through and re-attach the plastic cover.
-
-
-
Strip about an inch of insulation off of the snipped power cord and your replacement cord.
-
Twist each strand of wires together to keep them neat.
-
-
-
Twist together the wires from the replacement cord to the wires still attached to the blender.
-
Solder the connection if possible.
-
To reassemble your device, follow steps 1-5 in reverse order.