Troubleshooting
If you are having issues with this ventilator, please refer to our troubleshooting page.
Background and Identification
It is designed for use by severe respiratory illnesses. Their primary purpose is to provide optimal lung ventilation. As a source of continuous or short-term ventilatory support it is appropriate for institutional, homecare, military field hospitals and transportation settings. The LTV Series Ventilator has a lot of models and the model that I am introducing is LTV 1000 ventilator. The model of LTV ventilator is usually appearing on top right corner. It is easily identifiable by its size since it is not heavy.
- Here is the Quick Review on the Ventilator: LTV 1000 ventilator
- Here is the Set-Up on the Ventilator: LTV 1000 ventilator SET-UP
Contact Information: CareFusion and CareFusion Contact
Technical Specification
Physical
● Weight: 13.4 lbs
● Dimensions: 3" (H) x 10" (W) x 12" (D)
Controls
● Breath Types: Volume Control, Pressure Control, Pressure Support, Spontaneous
● Tidal Volume: 50-2000 ml
● Inspiration Time: 0.3-9.9 sec. (100 lpm)
● PC/PS/Spontaneous Flow: 160 lpm
● Pressure Control: 1-99 cmH2O
● Pressure Support: Off, 1-60 cmH2O
● Sensitivity: Off, 1-9 lpm
● % O2: 21%-100%
● Bias Flow: 0-20 cmH2O
● PEEP/CPAP: 0-20 cmH2O
● Insp/Exp Hold: 6 sec. max
● Manual Breath: 1 x current settings
● O2 Flush: 1-3 minutes
Variable Alarms
● Apnea Interval: 10-60 sec.
● High Pressure Limit: 5-100 cmH2O
● Low Peak Pressure: Off, 1-60 cmH2O
● Low Minute Volume: Off, 0.1-99 liters
● Alarm Volume: 60-85 dBA at 1 meter
● Alarm Silence/Reset: 60 seconds
● Ventilator Inoperative: Red LED, audible alarm
● High PEEP: Off, 3-40 cmH2O
● High Rate: Off, 5-80 cmH2O
Fixed Alarms
● Disconnect/Sense Line
● Low & Lost External Power
● Low & Empty Internal Battery
● High & Low Oxygen Inlet Pressure
● Dual Tones Patient Assist Alarm
Monitors and Indicators
● Peak Inspiratory Pressure: 0-120 cmH2O
● Mean Airway Pressure: 0-99 cmH2O
● PEEP: 0-99 cmH2O
● Total Breath Rate: 0-250 bpm
● Airway Pressure Display: -10-108 cmH2O
● Exhaled Tidal Volume: 0-4000 ml
● Exhaled Minute Volume: 0-99.9 liters
● IE Ratio: 99:1 - 1:99
Power Specifications
● 11 - 15 VDC, 90-250 VAC, 47-63 Hz
Standards and Regulatory Compliance
● ETC, cETL Listed
● ISO 13485 Registration
● IEC 601-2-12
● BSI Registered FM 45841
Source: Product Specifications
Here is the Video of Explained Words for LTV ventilator: LTV Ventilator Explained
Additional Information
- User manual: This page describes troubleshooting and replacement for the Pulmonetic LTV1000 ventilator
- Government of Canada: The page of Health Canada provides safety information on the LTV Series Ventilators.
- CareFusion: this page shows specifications and contact information of the device.
Additional Document
- Pulmonetic LTV 1000 Service Manual: Troubleshooting and Replacement page