Einleitung

  1. wWXqxDbWyNwvLSxM
    wWXqxDbWyNwvLSxM
    HMREwj2xfJW2EMDy
    VwnRblkgUaO1noCr
    • Remove the rubber decorative cap. It is attached with contact cement underneath. Isopropyl Alcohol may be used to soften the adhesive.

    • Unscrew the lock nut using a spanner wrench. The lock nut is reverse threaded.

    • Lift off the advance lever.

    • Remove the spring washer.

    • Remove one shim washer.

  2. 4PnNBKlEKkKxgnKK
    4PnNBKlEKkKxgnKK
    VDiHqTdMgnriQkOU
    • Set the mode dial to the 'L' position.

    • Use a spanner wrench to unscrew the dial lock nut.

    • Lift off the mode dial.

  3. kpyBgECwEPBeJCNY
    kpyBgECwEPBeJCNY
    DpPqAu4W5SHM5rb1
    WpADqDWTIT1Adfg5
    • Place a rigid object in the fork.

    • Unscrew the rewind lever.

    • Use a spanner wrench to remove the lock nut.

    • Lift off the exposure compensation dial.

  4. uqYL4YEGiXMQ6i1E
    uqYL4YEGiXMQ6i1E
    YFohY1dCawp1B5VP
    ACCaYTCf3ZBLYCe5
    • Remove two screws on either side of the eye piece.

    • Remove two screws on either side of the lens mount.

  5. ggynjNoNneoiPYLd
    ggynjNoNneoiPYLd
    LuGZbVAjGRlpu4Eg
    PC6STaLrToB1Be4R
    • Remove one screw by the exposure compensation dial.

    • Use a spanner wrench to remove the lock nut under the advance lever.

    • Lift off the top cover slowly. It is still attached by one wire.

    • Unsolder one gray flash sync wire.

  6. KUNoIXc5EZMbGRuZ
    • Remove three M1.7 x 3 mm screws.

    • Remove bottom cover.

  7. Sh3WOppPG4KHIUT5
    Sh3WOppPG4KHIUT5
    bcDAXFRYScYYBAFU
    5BLLoGwfXQhUTyQQ
    • Use a nickel or other large coin to remove the hand grip.

    • Drip isopropyl alcohol along the edge of the leatherette to soften the adhesive.

    • Use a dull scraper to lift one corner and pull off the panel.

    • Repeat on the rewind side of the camera.

    • Installation Notes: Use contact cement to reattach the leatherette after the camera has been fully reassembled and tested.

  8. Bxi5yDVKRwXM2NKG
    Bxi5yDVKRwXM2NKG
    sEXESZ5ZNEfHcEvf
    • Remove one M1.7 x 4.5 mm screw.

    • Remove one slotted screw.

    • Use isopropyl alcohol to soften the adhesive under the flex PCB.

    • Gently lift the PCB until it is free from the camera body.

  9. TSGqqIjD4ODQgumF
    • Unsolder one red wire.

    • Unsolder one light blue wire.

    • Unsolder one orange wire.

    • Unsolder one purple wire.

  10. iAtgXWvprOJ1wdDE
    iAtgXWvprOJ1wdDE
    lgnY6GNPjgJvfAFp
    • Remove one M1.7 x 4.5 mm screw.

    • Remove one M1.7 x 5 mm screw.

    • Remove one countersunk M1.7 x 5.5 mm screw.

    • Lift the contact terminal free from its seat.

    • Remove the tripod mount.

  11. TFidLDoBYdmnTGNI
    TFidLDoBYdmnTGNI
    ffWPZGdneUWnCZlH
    • Remove one slotted screw.

    • Remove one M1.7 x 4 mm screw.

    • Loosen one slotted screw (this will remain connected to the assembly).

    • Lift the ISO resistor assembly off the rewind post. It is still attached by a flex PCB.

  12. mZFIQ5A4R4HwAMbj
    mZFIQ5A4R4HwAMbj
    4XItLQFCyu3TrdHV
    okVO5nwLeQ1cpHYE
    • Remove one M1.7 x 2.5 mm screw. It is only accessible when the mode dial is in the 'L' position.

    • Remove one crosshead screw.

    • Lift the LCD out of the way. It is still attached by a flex PCB.

    • Remove one M1.7 x 2.5 mm screw.

    • Remove one slotted screw.

  13. FlZxgvBAPEqcKYOX
    FlZxgvBAPEqcKYOX
    LtyIoCYDAbBIRFUB
    • Unsolder one gray wire.

    • Unsolder one red wire.

    • Unsolder one brown wire.

    • Unsolder one white wire.

  14. KfwhHOQWkP3JWheZ
    KfwhHOQWkP3JWheZ
    KTcyuqNSpfWT64cD
    • Remove four M1.9 x 5 mm screws.

  15. RugMb3nMeHDH6UPQ
    RugMb3nMeHDH6UPQ
    ZExbmXVNJwcAmh2c
    • Remove two M1.7 x 2.5 mm screws.

    • Remove one M1.7 x 3.5 mm screw under the bottom plate.

    • Some versions of the camera may have an additional screw under the tripod mount that needs to be removed.

  16. 2S2t6oi2WI3RnLnb
    2S2t6oi2WI3RnLnb
    wKT3CKtfcMkDZBog
    • Wind the shutter

    • Make sure the mode dial unit and ISO selector unit are free from their mounting points.

    • Wiggle the mirror box and front board free.

    • Watch for wire snags as you pull it free.

    • Check for loose shim washers on the front board and note their position.

  17. KHXmfEdEGAppXsKj
    • Shutter should be in the charged state.

    • Mirror box should be in released state.

    • Pay close attention to wire routing during install.

    • To test the actuation of the mirror and shutter, wind the camera, then insert a tool into this slot and push the release lever to the left.

  18. UAdQGISGchhUItBX
    • Unsolder one orange and one blue wire for the mirror release solenoid.

    • Unsolder one pink wire for the LCD backlight.

    • Unsolder two purple wires for the TL switch.

    • Unsolder one green wire for the MD switch.

  19. nWRmZggyGXSqupfs
    • Unsolder six wires for the lens mount pin connections.

    • These are only present on the early production models. Later production models moved these connection points to the flex connector.

  20. KRkhTuJDHsstkbEJ
    KRkhTuJDHsstkbEJ
    4WuLEj4HMNFfWpQI
    • Unsolder two yellow wires for the aperture resistor.

  21. OTsgd3PToubHv2CZ
    OTsgd3PToubHv2CZ
    Y1QiSeGxXul2eXGY
    UoYuiSVSn5PP1G1Y
    • Unsolder the red and black wires for the metering cells in the eye piece.

    • Unsolder pink and green wires for the flash sync connections.

  22. yEVoqgjsdsFpclDs
    yEVoqgjsdsFpclDs
    5E63tqYaJIdoRWj1
    GdjtIHsgSv3jrBLe
    • Unsolder indicated wires from main flex PCB.

    • Remove one screw.

  23. kurInqU6OgsDbVaJ
    kurInqU6OgsDbVaJ
    pZhWbwP5xSHmQS3C
    • Remove two M1.4 x 2 mm screws.

    • Use a spudger to gently pry off the connector plate.

    • Remove the silicone insulating pad.

  24. hiCdNIxNFSfQTWqH
    • Remove two M1.4 x 1.6 mm screws.

    • Look for shim washers when removing and note their position.

  25. 4EsQli3YORKy4MPJ
    4EsQli3YORKy4MPJ
    2HJW5BNCqAbG5DIY
    UUZxRhpi5FmxbIEY
    • Remove one M1.7 x 4.5 mm screw.

    • Loosen one M1.7 x 4.5 mm screw but leave it in place.

    • Remove two M1.7 x 1.6 mm screws.

    • Remove the mirror governor.

    • Remove one plastic bushing.

  26. P2UkNPXGhvbEZQAA
    • Gently lift away the PCB from the mirror box.

    • The TTL flash metering cell needs to be unseated from the side of the mirror box to free the PCB for removal.

Abschluss

To reassemble your device, follow these instructions in reverse order.